Speed-controlled, universal vacuum controller for controlled evacuation of air (gas) from laboratory equipment, as well as for classical separation, filtration or drying tasks in the laboratory
The controller is ready-to-use in numerous applications and can be easily installed
VC 10 lite is only compatible with the vacuum pump VACSTAR digital
A cable connection between pump and controller is required
Manual and Programmable Mode available
Features:
Valve cleaning function for long service life
Integrated ventilation valve for simple pressure equalization and aeration with inert gas after process completion
VENT short key button allows pressure equalization during a running process
Program function: up to ten user-defined programs can be saved, with up to ten pressure/time sequences
USB / RS232 interfaces for connection with the laboratory software labworldsoft®
Electronic control system for improved process efficiency and higher solvent recovery rate
High energy efficiency thanks to device-to-device communication (vacuum controller to recirculating chiller)
For additional safety for users and environment, the use of the VSE 1 vacuum safety emission condenser is recommended, which prevents solvents from being released into the room air
The VSE 1 is available as an accessory
Gamma | Vacuümregelaars | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Nauwkeurigheid | 1 mbar | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Technische data |
Connection diameter suction side [mm] | 8 |
Connection diameter pressure side [mm] | 8 |
Connection diameter venting side [mm] | 8 |
Input pressure [mbar] | 1 - 1050 |
Boiling point detection | Nee |
Solvent library | Ja |
Two-point control | Nee |
Analog speed vacuum control | Ja |
Display | TFT |
Pressure unit / scale | mbar, hPa, mmHg, Torr |
Vacuum sensor | Ja |
Vacuum sensor type | ceramic Al2O3 |
Pressure max. for pressure sensor [bar] | 1.6 |
Measurement range (absolute) [mbar] | 1 - 1100 |
Control range [mbar] | 1 - 1100 |
Resolution pressure [mbar] | 1 |
Measurement uncertainty [mbar] | 1 |
Medium temperature (gas) [°C] | 5 - 40 |
Vacuum valve | Nee |
Venting valve | Ja |
Condensate trap | Nee |
Emission condenser | Nee |
Temperature measuring range max. [°C] | 200 |
Temperature measurement resolution [K] | 1 |
Accuracy of temperature measurement [K] | ±1 |
Timer | Ja |
Time setting min. [s] | 1 |
Time setting max. [min] | 6000 |
Vacuum speed control interface | VACSTAR |
Material in contact with medium | Al2O3, PTFE, FPM, PPS |
Housing material | PBT |
Clean room qualified | Nee |
Explosion proofed | Nee |
Fastening | stand / clamp |
Fastening diameter [mm] | 16 |
Mode automatic | Ja |
Mode manual | Ja |
Mode pump % | Ja |
Mode program | Ja |
Graph function | Ja |
Chiller control | Ja |
Vacuum leakage test | Ja |
Dimensions (W x H x D) [mm] | 95 x 150 x 110 |
Weight [kg] | 1.284 |
Permissible ambient temperature [°C] | 5 - 40 |
Permissible relative humidity [%] | 80 |
Protection class according to DIN EN 60529 | IP 20 |
RS 232 interface | Ja |
USB interface | Ja |
Analog output | Nee |
Voltage [V] | 100 - 240 |
Frequency [Hz] | 50/60 |
Power input [W] | 24 |
Power input standby [W] | 2 |
DC Voltage [V=] | 24 |
Current consumption [mA] | 1000 |
Speed-controlled, universal vacuum controller for controlled evacuation of air (gas) from laboratory equipment, as well as for classical separation, filtration or drying tasks in the laboratory
The controller is ready-to-use in numerous applications and can be easily installed
VC 10 lite is only compatible with the vacuum pump VACSTAR digital
A cable connection between pump and controller is required
Manual and Programmable Mode available
Features:
Valve cleaning function for long service life
Integrated ventilation valve for simple pressure equalization and aeration with inert gas after process completion
VENT short key button allows pressure equalization during a running process
Program function: up to ten user-defined programs can be saved, with up to ten pressure/time sequences
USB / RS232 interfaces for connection with the laboratory software labworldsoft®
Electronic control system for improved process efficiency and higher solvent recovery rate
High energy efficiency thanks to device-to-device communication (vacuum controller to recirculating chiller)
For additional safety for users and environment, the use of the VSE 1 vacuum safety emission condenser is recommended, which prevents solvents from being released into the room air
The VSE 1 is available as an accessory
Toebehoren
FAQ
Heb je vragen over dit product of over deze categorie? Op onze FAQ-sectie geven we je antwoord op veelgestelde vragen!
Bekijk de FAQJe kan onze experts altijd bereiken via info@imlab.eu
Of bel ons direct op +32 (0) 16 73 55 72
(Bereikbaar op werkdagen van 08:00 tot 17:00)
Stel direct je vraag
"*" geeft vereiste velden aan
Wij zijn Imlab
Imlab, verdeler gespecialiseerd in laboratoriummateriaal, biedt al 25 jaar lang producten van hoge kwaliteit en persoonlijke service
Mooie samenwerking met topmerken
Innovatieve en betrouwbare merken
Service op maat
Industrie, voeding, laboratorium, medisch...